SECTEURS
GEOTECHNICS
New ! 6G is arriving
New ! 6G is arriving
NOS CLIENTS
UEP42: Uranium Exploration
The UEP42 probe provides a set of data parameters responding perfectly to the needs of both uranium exploration and in-mine grade control. The probe is equipped with two complementary high and low sensitivity gamma radioactivity sensors to allow reliable results to be obtained over a wide range of uranium concentration values.
In addition, the probe provides borehole inclination and azimuth, as well as a focussed resistivity / chargeability measurement for the detection and evaluation of alteration zones.
Contact us to get a quote or request more information.
![UEP42 probe diagram](https://static.wixstatic.com/media/cadca1_d46a4f83b4c8426193e8d23b306b91e8~mv2.png/v1/fill/w_171,h_424,al_c,q_85,usm_0.66_1.00_0.01,enc_auto/uep42-illustration.png)
UEP42 PROBES SPECIFICATIONS
![Screenshot](https://static.wixstatic.com/media/cadca1_9e0ae29355e4488ba85b11849dc22b3e~mv2.png/v1/fill/w_74,h_86,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Capture%20d%E2%80%99e%CC%81cran%202020-11-02%20a%CC%80%2014_27_41_.png)
Technical Specifications
✓ Diameter : 42 mm
✓ Length : 2260 mm
✓ Weight : 11 Kg
✓ Max. Temp : 70°C
✓ Max Temp / Pressure : 70°C / 200 bar
![Screenshot](https://static.wixstatic.com/media/cadca1_9e0ae29355e4488ba85b11849dc22b3e~mv2.png/v1/fill/w_74,h_86,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Capture%20d%E2%80%99e%CC%81cran%202020-11-02%20a%CC%80%2014_27_41_.png)
Sensors Parameters
✓ Gamma detector #1 : ø25 x 50 mm NaI(Tl) crystal
✓ Gamma detector #2 : dual ZP1200 G-M tubes
✓ B/h inclination range/accuracy :0 to 180° / ± 0.5°
✓ B/h azimuth range/accuracy : 0 to 360° / ± 1°
✓ Resistivity injection signal : 200 Hz sine wave with ALC
✓ 0 to 25 kΩ·m (16-bit)
![Screenshot](https://static.wixstatic.com/media/cadca1_9e0ae29355e4488ba85b11849dc22b3e~mv2.png/v1/fill/w_74,h_86,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Capture%20d%E2%80%99e%CC%81cran%202020-11-02%20a%CC%80%2014_27_41_.png)
Options And Accessories
✓ Pre-delivery calibration : for Uppm
✓ Resistivity calibration box
![Screenshot](https://static.wixstatic.com/media/cadca1_9e0ae29355e4488ba85b11849dc22b3e~mv2.png/v1/fill/w_74,h_86,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Capture%20d%E2%80%99e%CC%81cran%202020-11-02%20a%CC%80%2014_27_41_.png)
Borehole Condition
✓ Dry or fluid-filled borehole : Resistivity in fluid-filled b/h onlyDry or fluid-filled borehole : Resistivity in fluid-filled b/h only
✓ Cased or open borehole : Open b/h required for resistivity